Burner
The GekaKonus® LSG-HP system is suitable for operation with burner using high speed diesel, heavy fuel oil, natural gas, LPG, biogas and bio diesel or using a dual fuel burner.
Permanent Monitoring

A permanent supervision of the following parameters

  • Steam pressure - Operation
  • Steam pressure - maximum
  • Steam temperature - super heating
  • Feed water inlet temperature - minimum
  • Feed water inlet pressure - Feed water pump
  • Exhaust gas temperature - high
  • Residue water blow down - Permanent
  • Burner - Flame monitoring
Continuous Blow Down
The blow down is obtained by a continuous process. Blow down of the quick steam generator is an absolute necessity to keep the access steam to the process heating system mostly free from residual moisture and dissolved salts.

Automatic Shut Down
In the event of any primary component or service failure, the safety devices will shut-down the entire system and provide visual and audible alarms.